Multi-Distance Veins Projection Based on Single Axis Camera and Projector System
Abstract
Every person has different location of veins, some veins are easily detected because it is visible due to thin tissue, and the other are invisible. This different location of veins causes intravenous access procedures and the procreas of intravenous therapy become longer. Multi-distance vein projections aim to simplify the measurement process where the device and object do not have to be at a certain distance. Some research that has been done especially for real-time vein projection does not conduct how the characteristics of projection at different distances. In this paper, we propose a method for performing multi-distance real-time back-projection by using the intersection between camera and projector. This method equiped with an ultrasonic distance sensor to identify the projection characteristic in any distance. In its implementation, this method is able to project at a distance of 20-40 cm with a maximum projection error of 0.6 mm. The measurement angle tolerance between the object and the device is ±5 degrees with a maximum error of 0.7 mm.Downloads
References
Min Joung Kim et al., Efficacy of VeinViewer in pediatric peripheral intravenous access: A randomized controlled trial, Eur. J. Pediatr., vol. 171, no. 7, pp. 1121–1125, 2012.
Simon Juric and Borut Zalik, An innovative approach to near-infrared spectroscopy using a standard mobile device and its clinical application in the real-time visualization of peripheral veins, BMC Med. Inform. Decis. Mak., vol. 14, no. 1, pp. 1–9, 2014. DOI: https://doi.org/10.1186/s12911-014-0100-z
Herbert D. Zeman, Prototype vein contrast enhancer, Opt. Eng., vol. 44, no. 8, p. 086401, 2005.
Xaobin Dai, Ya Zhou, Xiaoming Hu, Meiqing Liu, Xia Zhu, and Zhaogou Wu, A fast vein display device based on the camera-projector system, IST 2013 - 2013 IEEE Int. Conf. Imaging Syst. Tech. Proc., pp. 146–149, 2013.
D. Ai et al., Augmented reality based real-time subcutaneous vein imaging system, Biomed. Opt. Express, vol. 7, no. 7, p. 2565, 2016. DOI: https://doi.org/10.1364/BOE.7.002565
I Putu Adi Surya Gunawan, Riyanto Sigit, and Agus Indra Gunawan, Vein Visualization System Using Camera and Projector Based on Distance Sensor, in 2018 International Electronics Symposium on Engineering Technology and Applications (IES-ETA), 2018, pp. 150–156. DOI: https://doi.org/10.1109/ELECSYM.2018.8615501
Scott Prahl, Optical Arbsorption of Hemoglobin, 1999. [Online]. Available: https://omlc.org/spectra/hemoglobin/. [Accessed: 21-Jan-2018].
Donghoon Kim, Yujin Kim, Siyeop Yoon, and Deukhee Lee, Preliminary study for designing a novel vein-visualizing device, Sensors (Switzerland), vol. 17, no. 2, 2017. DOI: https://doi.org/10.3390/s17020304
Liukui Chen, Jing Wang, Shiyu Yang, and Haibo He, A Finger Vein Image-Based Personal Identification System with Self-Adaptive Illuminance Control, IEEE Trans. Instrum. Meas., vol. 66, no. 2, pp. 294–304, 2017. DOI: https://doi.org/10.1109/TIM.2016.2622860
Yiding Wang, Yun Fan, Weiping Liao, Kafeng Li, Lik-Kwan Shark, and Martin R. Varley, Hand vein recognition based on multiple keypoints sets, Proc. - 2012 5th IAPR Int. Conf. Biometrics, ICB 2012, pp. 367–371, 2012. DOI: https://doi.org/10.1109/ICB.2012.6199778
Anagha. B. Bawase and P. S. D. Apte, Infrared Hand Vein Detection System, pp. 48–52, 2015.
Adam Shidqul Aziz, Riyanto Sigit, Achmad Basuki, and Taufik Hidayat, Cardiac Motions Classification on Sequential PSAX Echocardiogram, Indones. J. Electr. Eng. Comput. Sci., vol. 12, no. 3, pp. 1289–1296, 2018.
Galih Hendra Wibowo, Riyanto Sigit, and Ali Ridho. Barakbah, Javanese Character Feature Extraction Based on Shape Energy, EMITTER International Journal Engineering Technology, vol. 5, no. 1, pp. 154–170, 2017. DOI: https://doi.org/10.24003/emitter.v5i1.175
Muqing Zhou, Zhaogou Wu, Difan Chen, and Ya Zhou, An improved vein image segmentation algorithm based on SLIC and Niblack threshold method, Proc. SPIE 9045, 2013 Int. Conf. Opt. Instruments Technol. Optoelectron. Imaging Process. Technol., vol. 9045, p. 90450D, 2013.
George. J. Tserevelakis et al., Photoacoustic imaging reveals hidden underdrawings in paintings, Sci. Rep., vol. 7, no. 1, pp. 1–11, 2017. DOI: https://doi.org/10.1038/s41598-017-00873-7
Rebecca. Sharp et al., Measurement of Vein Diameter for Peripherally Inserted Central Catheter (PICC) Insertion: An Observational Study, J. Infus. Nurs., vol. 38, no. 5, pp. 351–357, 2015. DOI: https://doi.org/10.1097/NAN.0000000000000125
Copyright (c) 2019 EMITTER International Journal of Engineering Technology
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
The copyright to this article is transferred to Politeknik Elektronika Negeri Surabaya(PENS) if and when the article is accepted for publication. The undersigned hereby transfers any and all rights in and to the paper including without limitation all copyrights to PENS. The undersigned hereby represents and warrants that the paper is original and that he/she is the author of the paper, except for material that is clearly identified as to its original source, with permission notices from the copyright owners where required. The undersigned represents that he/she has the power and authority to make and execute this assignment. The copyright transfer form can be downloaded here .
The corresponding author signs for and accepts responsibility for releasing this material on behalf of any and all co-authors. This agreement is to be signed by at least one of the authors who have obtained the assent of the co-author(s) where applicable. After submission of this agreement signed by the corresponding author, changes of authorship or in the order of the authors listed will not be accepted.
Retained Rights/Terms and Conditions
- Authors retain all proprietary rights in any process, procedure, or article of manufacture described in the Work.
- Authors may reproduce or authorize others to reproduce the work or derivative works for the author’s personal use or company use, provided that the source and the copyright notice of Politeknik Elektronika Negeri Surabaya (PENS) publisher are indicated.
- Authors are allowed to use and reuse their articles under the same CC-BY-NC-SA license as third parties.
- Third-parties are allowed to share and adapt the publication work for all non-commercial purposes and if they remix, transform, or build upon the material, they must distribute under the same license as the original.
Plagiarism Check
To avoid plagiarism activities, the manuscript will be checked twice by the Editorial Board of the EMITTER International Journal of Engineering Technology (EMITTER Journal) using iThenticate Plagiarism Checker and the CrossCheck plagiarism screening service. The similarity score of a manuscript has should be less than 25%. The manuscript that plagiarizes another author’s work or author's own will be rejected by EMITTER Journal.
Authors are expected to comply with EMITTER Journal's plagiarism rules by downloading and signing the plagiarism declaration form here and resubmitting the form, along with the copyright transfer form via online submission.